Electrical Specifications |
Model(SPHC) |
lkw |
1.5kw |
2kw |
3kw |
4kw |
5KW |
6KW |
Rated output power(W) |
1000W |
1500W |
2000W |
3000W |
4000W |
5000W |
6000W |
Rated input voltage |
12VDC/24VDC/48VDC |
12VDC/24VDC/48VDC |
24VDC/48VDC |
Mains mode specifications: |
Input voltage waveform |
Sine wave (mains or generator) |
Rated input voltage |
100V/110V/120V/220V/230V/240Vac |
Low voltage cut-off point |
92/184Vac±4% |
Low pressure recovery point |
97/194Vac ±4% |
High voltage cut-off point |
127/253Vac±4% |
High voltage recovery point |
121/243Vac±4% |
Maximum AC input voltage |
135/270V rms |
Rated input frequency |
50Hz/60Hz(automatic detection) |
Low voltage recovery point frequency |
40.5±0.3Hz ; |
Low voltage cut-off frequency |
40±0.3Hz; |
High voltage recovery point frequency |
69.5±0.3Hz; |
High voltage cut-off frequency |
70±0.3Hz ; |
Output voltage waveform |
Consistent with input voltage waveform |
Overload protection |
Circuit breaker start |
Short circuit protection |
Circuit breaker start |
Power Efficiency |
>95% |
Converting current |
30A |
Conversion time (Ac to Dc) |
10ms |
Conversion time (Dc to Ac) |
10ms |
Bypass switching current |
have |
Bypass maximum load current |
30A |
Output voltage waveform |
Sine Wave |
Power Factor |
0~1.0 |
Rated output voltage(V) |
120/230Vac |
Rated output frequency(Hz) |
60/50Hz±0.3Hz |
Automatically track main frequency (Hz) |
Yes (from the first connection) |
Output voltage range |
±2%rms |
efficiency |
>80% |
Overload protection (SMPS load) |
(110%<load<125%)±10%: disconnect output voltage after 15 minutes (125%<load<150%)±10%: disconnect output voltage after 10 secondsLoad > 150% ± 10%: disconnect output voltage after 20 seconds |
Peak CapacityQuantity (10s) |
3000VA |
4500VA |
6000VA |
9000VA |
1200VA |
15000VA |
18000VA |
start the motor |
1HP |
1.5HP |
2HP |
3HP |
4HP |
5HP |
6HP |
Short circuit protection |
Current limit (power off after 10s) |
Circuit breaker size |
15A |
20A |
30A |
40A |
Rated DC input voltage |
12V/24V/48V |
Minimum DC terminal voltage |
10V/20V/40V |
Undervoltage warning |
10.5Vdc ±0.3Vdc (12V power supply) |
The DC input voltage is too low.Automatic power-off |
10.0Vdc ±0.3Vdc (12V power supply) |
Input overvoltage warning and power off |
16Vdc ±0.3Vdc (12V power supply) |
Input overvoltage recovery |
15.5Vdc ±0.3Vdc (12V power supply) |
Power saving |
Load ≤2W |
Inverter dimensions(Length*Width*Height) |
360*185*180mm |
420*185*180mm |
597*195*190mm |
Packing size (length*width*height) |
520*315*305 |
580*315*305mm |
760*325*310mm |
Inverter weight |
13.5KG |
14KG |
17KG |
21KG |
27KG |
29.5KG |
30.5KG |
Package running weight |
15.5KG |
15.5KG |
19KG |
23.5KG |
29.5KG |
31.5KG |
32.5KG |
Standard warranty |
2 years |