Technical Parameters |
Electrical parameters |
Inverter Device inputout |
Model SP-PV |
1.0KW |
2.0KW |
3.0KW |
4.0KW |
5.0KW |
6.0KW |
8.0KW |
10.0KW |
12.0KW |
rated power |
1.0KW |
2.0KW |
3.0KW |
4.0KW |
5.0KW |
6.0KW |
8.0KW |
10.0KW |
12.0KW |
Peak power (2 seconds) |
3.0KW |
6.0KW |
9.0KW |
12.0KW |
15.0KW |
18.0KW |
24.0KW |
30.0KW |
36.0KW |
Output voltage waveform |
Pure sine wave (mains or generator) |
Rated efficiency |
>88%(Peak) |
Online Mode Efficiency |
>95% |
Power Factor |
0.9-1.0 |
Rated output voltage |
100-110-120Vac /220-230-240Vac |
Output frequency |
50Hz ±0.3Hz/60Hz ±0.3Hz |
Short circuit protection |
Yes, short circuit protection after 1 second |
Typical switching time |
10ms(max) |
Total Harmonic Distortion |
<10% |
DCenter |
Rated input voltage |
12.0Vdc /24.0Vdc/48.0Vdc |
24.0Vdc /48.0Vdc |
48.0Vdc/60.0Vdc/72.0Vdc |
Minimum starting voltage |
10.0Vdc /10.5Vdc for12Vdc Mode |
*2 for 24Vdc,*4 for 48Vdc*5 |
|
Low battery voltage alarm |
10.5Vdc /11.0Vdc for12Vdc Mode |
60VdcVdc *672Vdc |
Low voltage cut-out |
10.0Vdc /10.5Vdc for12Vdc Mode |
High voltage cutting |
16.0Vdc for 12Vdc Mode |
Low voltage recovery |
15.5Vdc for 12Vdc Mode |
Charge controlDevice |
The output voltage |
Depends on battery type |
Charging circuit breaker specifications |
15A |
20A |
30A |
40A |
40A |
40A |
50A |
80A |
80A |
Maximum charging current |
See detailed table |
Starting voltage |
10.5 -15.7Vdc for12Vdc Mode |
*2 for 24Vdc,*4 for 48Vdc;*672Vdc |
Overcharge protection cut-off point |
Greater than 15.8Vdc for 12Vdc Mode |
Protect |
Rated input voltage |
100-110-120Vac /220-230-240Vac |
Maximum input voltage |
150VAC For 120Vac LV Mode;300VAC For 230Vac HV Mode; |
Rated input frequency |
50Hz or 60Hz |
Low frequency cut-out |
47±0.3Hz for 50Hz,57±0.3Hz for 60Hz |
High frequency cut-out |
55±0.3Hz for 50Hz,65±0.3Hz for 60Hz |
Overload protection |
have |
Output short circuit protection |
have |
Maximum bypass current |
30Amp |
40Amp |
80Amp |
sun Controllable Deviceparameter |
Solar system voltage |
MPPT12V/24V/36V/48V automatic identification |
Photovoltaic panel open circuit voltage |
18~150Vdc@12V 35~150Vdc@24V60~150Vdc@48V |
Rated charging current |
30A-120A (optional) |
Charging efficiency |
97.6% |
Rechargeable battery type |
Valve Regulated Lead Acid Battery Gel Battery Lithium Battery |
charging method |
Four-stage charging: constant current charging, constant voltage charging, floating charging, equalizing charging |
safety protection |
Solar panel short circuit protection, overcharge protection, over discharge protection, overload protection |
mechanicalparameter |
Install |
Wall Mount |
Inverter size (length*width*high) |
340*420*200mm |
425*375*200mm |
560*420*235mm |
655*490*240mm |
Inverter housing size(Length*Width*Height) |
415*440*300mm |
500*495*300mm |
660*470*310mm |
720*470*290mm |
Inverter with solar powerNet weight KG |
16 |
20 |
26.5 |
31.5 |
33.5 |
37.5 |
56.5 |
58.5 |
61.5 |
Package includes solar panelNet weight KG |
19 |
29.5 |
38 |
40 |
44 |
63.5 |
66 |
68.5 |
70.5 |
show |
Status LEDs / Status LEDs+LCD |
Standard warranty |
2 years |